How to Change the Water in a Laser Welder Chiller?
Every laser equipment manufacturer knows that the laser source is the most important core component of a laser welder, so protecting it is extremely important. The prerequisite for proper laser maintenance is
making sure the chiller closely tied to it has its deionized water replaced on schedule, because the purity of the cooling water is the key to guaranteeing the service life of the laser cavity components, laser output and
welding quality. Next, here is a detailed walkthrough of exactly how to replace the deionized water.
First, set the multimeter to the 2 MΩ resistance range, hold the exposed metal tips of the two probes 1 cm apart, then insert them in parallel into the cooling water surface. At this point pay attention to
the resistance reading: if it drops below 250 kΩ, replace the cooling water immediately, and the fresh pure water must have a conductivity of 32 MΩ·cm. In principle, the chiller water
should be replaced once a month, but in practice check the conductivity of the internal circulating water at least once a week and keep it at 30.5 MΩ·cm.

In daily operation of the laser welder, watch for frost forming on the chiller's titanium tube. If frost appears, it is most likely a result of insufficient
Freon in the refrigeration system. Do not blindly take the machine apart to check it yourself; instead have a professional inspect the equipment. This is exactly where the after-sales